Type | Variant | ||||
---|---|---|---|---|---|
6.12.6 25 APK | |||||
Size: 7.2 MB Certificate: d867af74208a29bd461f126cbab81cdd76854999 SHA1 signature: 4db5b1a7172a523668726e247db461dfabc26c54 Architecture: arm64-v8a Screen DPI: mdpi (160dpi), hdpi (240dpi), xhdpi (320dpi), xxhdpi (480dpi), xxxhdpi (640dpi) Device: laptop, tablet, phone | |||||
6.12.6 25 APK | |||||
Size: 7.37 MB Certificate: d867af74208a29bd461f126cbab81cdd76854999 SHA1 signature: 1ab3a5a6c9c43d389dffb935f476c6412c0467a6 Architecture: x86_64 Screen DPI: mdpi (160dpi), hdpi (240dpi), xhdpi (320dpi), xxhdpi (480dpi), xxxhdpi (640dpi) Device: laptop, tablet, phone | |||||
6.12.6 25 APK | |||||
Size: 6.96 MB Certificate: d867af74208a29bd461f126cbab81cdd76854999 SHA1 signature: 0d8fcb88727a6bff9008e6897b4a0e5a2f6e8bdb Architecture: armeabi-v7a Screen DPI: mdpi (160dpi), hdpi (240dpi), xhdpi (320dpi), xxhdpi (480dpi), xxxhdpi (640dpi) Device: laptop, tablet, phone | |||||
6.12.6 25 XAPK | |||||
Size: 481.92 KB XAPK: 21.59 MB Certificate: d867af74208a29bd461f126cbab81cdd76854999 SHA1 signature: d2fa5f58dc6ba1b032a7d33197f1d6f72478ca59 Architecture: x86_64, arm64-v8a, armeabi-v7a Screen DPI: ldpi (120dpi), mdpi (160dpi), tvdpi (213dpi), hdpi (240dpi), xhdpi (320dpi), xxhdpi (480dpi), xxxhdpi (640dpi) Device: phone |
Download MP8000 APK free
Monitor and control the MP8000 Bluetooth Overload Relay on your Android™ Device.
Monitor and control the MP8000 Bluetooth Overload Relay on your Android™ device. Use the MP8000 app to configure the relay, view real-time data, and troubleshoot fault codes via a Bluetooth interface in the relay. No need to open the control panel. Keeping the panel door closed, keeps workers safer from the dangers of arc flash. The app has a range of 30 feet so workers can stay far away from the panel and can even stay in their vehicle in remote applications.
Easily pair multiple MP8000 Relays to your Android™ device
Stand next to the motor or pump – not the relay – to monitor equipment startup on new installations
Improve safety: monitor your motor or pump from 30 feet away
Reduce set up time with less wiring
PAIRING
Pairing is safe and secure. Pair with Google Android™ (version 4.3 and higher) smartphone or tablet. A unique pairing code is printed on the side label found on the MP8000 relay.
MP8000 RELAY
The MP8000 enhanced overload relay protects any motor drawing 0.5-1,000 full load Amps (external CTs are required above 100 Amps). It is designed for single or 3-phase systems with operating voltages of 90-690 VAC (use of external potential transformers can extend upper voltage range above 690 VAC). Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application.
PROTECTION FROM
Overload (Overpower)
Underload (Underpower)
Overcurrent/Jam
Undercurrent
Current Unbalance
Phase Loss
Phase Reversal
Overvoltage
Under voltage
Voltage Unbalance
Rapid Cycling/Jog
Contactor Failure
Zero-Sequence Ground Fault
PTC Motor Overtemperature
WHAT CUSTOMERS ARE SAYING
“This is a HUGE opportunity. During a new installation, I can be right next to the motor at start up to see if it’s binding (or other problems) and shut it off immediately”
Easily pair multiple MP8000 Relays to your Android™ device
Stand next to the motor or pump – not the relay – to monitor equipment startup on new installations
Improve safety: monitor your motor or pump from 30 feet away
Reduce set up time with less wiring
PAIRING
Pairing is safe and secure. Pair with Google Android™ (version 4.3 and higher) smartphone or tablet. A unique pairing code is printed on the side label found on the MP8000 relay.
MP8000 RELAY
The MP8000 enhanced overload relay protects any motor drawing 0.5-1,000 full load Amps (external CTs are required above 100 Amps). It is designed for single or 3-phase systems with operating voltages of 90-690 VAC (use of external potential transformers can extend upper voltage range above 690 VAC). Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application.
PROTECTION FROM
Overload (Overpower)
Underload (Underpower)
Overcurrent/Jam
Undercurrent
Current Unbalance
Phase Loss
Phase Reversal
Overvoltage
Under voltage
Voltage Unbalance
Rapid Cycling/Jog
Contactor Failure
Zero-Sequence Ground Fault
PTC Motor Overtemperature
WHAT CUSTOMERS ARE SAYING
“This is a HUGE opportunity. During a new installation, I can be right next to the motor at start up to see if it’s binding (or other problems) and shut it off immediately”
Show more
What´s new
• Small bug and display fixes
• Power Factor now displays averaged value for 3-Phase users
• Updates to keep app compatible with fw v3.11
• Included link to manual
• Fix incorrect power factors displayed in fault logs of LPF & LIN when in 3-phase mode
• Power Factor now displays averaged value for 3-Phase users
• Updates to keep app compatible with fw v3.11
• Included link to manual
• Fix incorrect power factors displayed in fault logs of LPF & LIN when in 3-phase mode
More info
Updated in
2022-03-29
Size
7.2 MB
Current version
6.12.6
Requires Android
4.4 and up
Content Rating
Everyone
Offered By
Littelfuse
Developer [email protected]